FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package kbv.mio.emp#1.0.0-kommentierung.1 (141 ms)

Package kbv.mio.emp
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=kbv.mio.emp@1.0.0-kommentierung.1&canonical=https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Composition
Url https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Composition
Version 1.0.0
Status draft
Name KBV_PR_MIO_EMP_Composition
Title KBV_PR_MIO_EMP_Composition
Experimental False
Description Dieses Profil bildet das aus dem eMedikationsplan-Export resultierende Dokument ab.
Copyright Im folgenden Profil können Codes aus den Codesystemen Snomed, Loinc oder Ucum enthalten sein, die dem folgenden Urheberrecht unterliegen: This material includes SNOMED Clinical Terms® SNOMED CT® which is used by permission of SNOMED International. All rights reserved. SNOMED CT®, was originally created by The College of American Pathologists. SNOMED and SNOMED CT are registered trademarks of SNOMED International. Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license. This material contains content from Loinc http://loinc.org. Loinc is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes Loinc Committee and is available at no cost under the license at http://loinc.org/license. Loinc® is a registered United States trademark of Regenstrief Institute, Inc. This product includes all or a portion of the UCUM table, UCUM codes, and UCUM definitions or is derived from it, subject to a license from Regenstrief Institute, Inc. and The UCUM Organization. Your use of the UCUM table, UCUM codes, UCUM definitions also is subject to this license, a copy of which is available at ​http://unitsofmeasure.org. The current complete UCUM table, UCUM Specification are available for download at ​http://unitsofmeasure.org. The UCUM table and UCUM codes are copyright © 1995-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures UCUM Organization. All rights reserved. THE UCUM TABLE IN ALL FORMATS, UCUM DEFINITIONS, AND SPECIFICATION ARE PROVIDED "AS IS." ANY EXPRESS OR IMPLIED WARRANTIES ARE DISCLAIMED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Type Composition
Kind resource

Resources that use this resource

StructureDefinition
https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Provenance KBV_PR_MIO_EMP_Provenance

Resources that this resource uses

StructureDefinition
http://fhir.de/StructureDefinition/identifier-kvid-10 Identifier-Profil für die 10-stellige Krankenversichertennummer
https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_List_AllergyIntolerance KBV_PR_MIO_EMP_List_AllergyIntolerance
https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_List_Medication KBV_PR_MIO_EMP_List_Medication
https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_List_Observation KBV_PR_MIO_EMP_List_Observation
https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Observation_Medication_Management_Note KBV_PR_MIO_EMP_Observation_Medication_Management_Note
https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Provenance KBV_PR_MIO_EMP_Provenance


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "KBV-PR-MIO-EMP-Composition",
  "url" : "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Composition",
  "version" : "1.0.0",
  "name" : "KBV_PR_MIO_EMP_Composition",
  "title" : "KBV_PR_MIO_EMP_Composition",
  "status" : "draft",
  "publisher" : "Kassenärztliche Bundesvereinigung (KBV)",
  "description" : "Dieses Profil bildet das aus dem eMedikationsplan-Export resultierende Dokument ab.",
  "copyright" : "Im folgenden Profil können Codes aus den Codesystemen Snomed, Loinc oder Ucum enthalten sein, die dem folgenden Urheberrecht unterliegen: This material includes SNOMED Clinical Terms® SNOMED CT® which is used by permission of SNOMED International. All rights reserved. SNOMED CT®, was originally created by The College of American Pathologists. SNOMED and SNOMED CT are registered trademarks of SNOMED International. Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license. This material contains content from Loinc http://loinc.org. Loinc is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes Loinc Committee and is available at no cost under the license at http://loinc.org/license. Loinc® is a registered United States trademark of Regenstrief Institute, Inc. This product includes all or a portion of the UCUM table, UCUM codes, and UCUM definitions or is derived from it, subject to a license from Regenstrief Institute, Inc. and The UCUM Organization. Your use of the UCUM table, UCUM codes, UCUM definitions also is subject to this license, a copy of which is available at ​http://unitsofmeasure.org. The current complete UCUM table, UCUM Specification are available for download at ​http://unitsofmeasure.org. The UCUM table and UCUM codes are copyright © 1995-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures UCUM Organization. All rights reserved. THE UCUM TABLE IN ALL FORMATS, UCUM DEFINITIONS, AND SPECIFICATION ARE PROVIDED \"AS IS.\" ANY EXPRESS OR IMPLIED WARRANTIES ARE DISCLAIMED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.",
  "fhirVersion" : "4.0.1",
  "kind" : "resource",
  "abstract" : false,
  "type" : "Composition",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Composition",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Composition",
        "path" : "Composition",
        "definition" : "Dieses Profil bildet das aus dem eMedikationsplan-Export resultierende Dokument ab.",
        "constraint" : [
          {
            "key" : "date-1",
            "severity" : "error",
            "human" : "Datetime must be at least day, month and year.",
            "expression" : "(date as dateTime).toString().length() >= 10",
            "source" : "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Composition"
          }
        ]
      },
      {
        "id" : "Composition.meta",
        "path" : "Composition.meta",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.meta.versionId",
        "path" : "Composition.meta.versionId",
        "mustSupport" : true
      },
      {
        "id" : "Composition.meta.lastUpdated",
        "path" : "Composition.meta.lastUpdated",
        "mustSupport" : true
      },
      {
        "id" : "Composition.meta.profile",
        "path" : "Composition.meta.profile",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 1
      },
      {
        "id" : "Composition.meta.profile:mioProfile",
        "path" : "Composition.meta.profile",
        "sliceName" : "mioProfile",
        "min" : 1,
        "max" : "1",
        "patternCanonical" : "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Composition|1.0.0"
      },
      {
        "id" : "Composition.text",
        "path" : "Composition.text",
        "definition" : "In diesem Element können die, in der Instanz, enthaltenen Informationen in einer menschenlesbaren Form zusammengefasst werden. Dabei ist zu beachten, dass keine Informationen aufgenommen werden dürfen, die nicht in strukturierter Form an anderer Stelle in der Instanz enthalten sind."
      },
      {
        "id" : "Composition.text.status",
        "path" : "Composition.text.status",
        "fixedCode" : "extensions"
      },
      {
        "id" : "Composition.status",
        "path" : "Composition.status",
        "patternCode" : "final"
      },
      {
        "id" : "Composition.type",
        "path" : "Composition.type",
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "736378000",
              "system" : "http://snomed.info/sct",
              "version" : "http://snomed.info/sct/900000000000207008/version/20230731",
              "display" : "Medication management plan (record artifact)"
            }
          ]
        },
        "mustSupport" : true
      },
      {
        "id" : "Composition.type.coding",
        "path" : "Composition.type.coding",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.type.coding.system",
        "path" : "Composition.type.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.type.coding.version",
        "path" : "Composition.type.coding.version",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.type.coding.code",
        "path" : "Composition.type.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.type.coding.display",
        "path" : "Composition.type.coding.display",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.subject",
        "path" : "Composition.subject",
        "min" : 1,
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Patient"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Composition.subject.identifier",
        "path" : "Composition.subject.identifier",
        "min" : 1,
        "type" : [
          {
            "code" : "Identifier",
            "profile" : [
              "http://fhir.de/StructureDefinition/identifier-kvid-10"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Composition.date",
        "path" : "Composition.date",
        "mustSupport" : true
      },
      {
        "id" : "Composition.title",
        "path" : "Composition.title",
        "fixedString" : "Medikationsplan"
      },
      {
        "id" : "Composition.section",
        "path" : "Composition.section",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "code"
            }
          ],
          "rules" : "closed"
        },
        "min" : 3,
        "max" : "5",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege",
        "path" : "Composition.section",
        "sliceName" : "allergieUnvertraeglichkeitAMTSrZIEintraege",
        "definition" : "Hier wird eine Liste von Allergien/Unverträglichkeiten referenziert, die für eine AMTS (Arzneimitteltherapiesicherheit)-Prüfung relevant sind. Diese Liste enthält alle AMTS-relevanten Allergien/Unverträglichkeiten-Einträge einer/eines Patient:in.",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.title",
        "path" : "Composition.section.title",
        "min" : 1,
        "fixedString" : "Allergien/Unverträglichkeiten-Liste-Einträge",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.code",
        "path" : "Composition.section.code",
        "min" : 1,
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "SectionAMTSRZIAllergienUnvertraeglichkeiten",
              "system" : "https://fhir.kbv.de/CodeSystem/KBV_CS_MIO_EMP_Section_Codes",
              "version" : "1.0.0",
              "display" : "Bereich AMTS-relevante Zusatzinformationen - Allergien/Unverträglichkeiten"
            }
          ]
        },
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.code.coding",
        "path" : "Composition.section.code.coding",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.code.coding.system",
        "path" : "Composition.section.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.code.coding.version",
        "path" : "Composition.section.code.coding.version",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.code.coding.code",
        "path" : "Composition.section.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.code.coding.display",
        "path" : "Composition.section.code.coding.display",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.entry",
        "path" : "Composition.section.entry",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_List_AllergyIntolerance|1.0.0"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:allergieUnvertraeglichkeitAMTSrZIEintraege.entry.reference",
        "path" : "Composition.section.entry.reference",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege",
        "path" : "Composition.section",
        "sliceName" : "beobachtungenMessungenAMTSrZIEintraege",
        "definition" : "Hier wird eine Liste von Beobachtungen/Messungen referenziert, die AMTS (Arzneimitteltherapiesicherheit)-Prüfungs-relevante, klinische Zusatzinformationen abbilden. Diese Liste enthält alle AMTS-Prüfungs-relevanten Beobachtungen/Messungen einer/eines Patient:in.",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.title",
        "path" : "Composition.section.title",
        "min" : 1,
        "fixedString" : "Beobachtungen/Messungen-Liste-Einträge",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.code",
        "path" : "Composition.section.code",
        "min" : 1,
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "SectionAMTSRZIBeobachtungenMessungen",
              "system" : "https://fhir.kbv.de/CodeSystem/KBV_CS_MIO_EMP_Section_Codes",
              "version" : "1.0.0",
              "display" : "Bereich AMTS-relevante Zusatzinformationen - Beobachtungen/Messungen"
            }
          ]
        },
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.code.coding",
        "path" : "Composition.section.code.coding",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.code.coding.system",
        "path" : "Composition.section.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.code.coding.version",
        "path" : "Composition.section.code.coding.version",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.code.coding.code",
        "path" : "Composition.section.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.code.coding.display",
        "path" : "Composition.section.code.coding.display",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.entry",
        "path" : "Composition.section.entry",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_List_Observation|1.0.0"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:beobachtungenMessungenAMTSrZIEintraege.entry.reference",
        "path" : "Composition.section.entry.reference",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege",
        "path" : "Composition.section",
        "sliceName" : "medikationsEintraege",
        "definition" : "Hier wird eine Liste von Medikation-Informationen referenziert. Diese Liste enthält alle Medikations-Informations-Einträge einer/eines Patient:in.",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.title",
        "path" : "Composition.section.title",
        "min" : 1,
        "fixedString" : "Medikations-Informationen-Liste-Einträge",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.code",
        "path" : "Composition.section.code",
        "min" : 1,
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "721912009",
              "system" : "http://snomed.info/sct",
              "version" : "http://snomed.info/sct/900000000000207008/version/20230731",
              "display" : "Medication summary document (record artifact)"
            }
          ]
        },
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.code.coding",
        "path" : "Composition.section.code.coding",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.code.coding.system",
        "path" : "Composition.section.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.code.coding.version",
        "path" : "Composition.section.code.coding.version",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.code.coding.code",
        "path" : "Composition.section.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.code.coding.display",
        "path" : "Composition.section.code.coding.display",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.entry",
        "path" : "Composition.section.entry",
        "min" : 1,
        "max" : "1",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_List_Medication|1.0.0"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:medikationsEintraege.entry.reference",
        "path" : "Composition.section.entry.reference",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege",
        "path" : "Composition.section",
        "sliceName" : "herkunftsEintraege",
        "definition" : "Hier werden die für die Medikations-Einträge relevanten Herkunftsinformationen referenziert. Dabei handelt es sich beispielweise um die Quelle bzw. die Ursprungs-Information des Medikations-Informationen-Eintrags sowie die an der Erstellung oder Bearbeitung eines Medikations-Informationen-Eintrags beteiligten Personen.",
        "min" : 0,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.title",
        "path" : "Composition.section.title",
        "min" : 1,
        "fixedString" : "Herkunftsinformations-Einträge",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.code",
        "path" : "Composition.section.code",
        "min" : 1,
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "SectionHerkunftsinformationEintraege",
              "system" : "https://fhir.kbv.de/CodeSystem/KBV_CS_MIO_EMP_Section_Codes",
              "version" : "1.0.0",
              "display" : "Herkunftsinformation-Einträge"
            }
          ]
        },
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.code.coding",
        "path" : "Composition.section.code.coding",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.code.coding.system",
        "path" : "Composition.section.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.code.coding.version",
        "path" : "Composition.section.code.coding.version",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.code.coding.code",
        "path" : "Composition.section.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.code.coding.display",
        "path" : "Composition.section.code.coding.display",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.entry",
        "path" : "Composition.section.entry",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Provenance|1.0.0"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:herkunftsEintraege.entry.reference",
        "path" : "Composition.section.entry.reference",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege",
        "path" : "Composition.section",
        "sliceName" : "hinweisEintraege",
        "definition" : "Hier werden die übergreifenden Hinweise die für den Medikationsplan zu beachten sind referenziert.",
        "min" : 0,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.title",
        "path" : "Composition.section.title",
        "min" : 1,
        "fixedString" : "Ãœbergreifende Hinweise",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.code",
        "path" : "Composition.section.code",
        "min" : 1,
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "SectionUebergreifendeHinweiseEintraege",
              "system" : "https://fhir.kbv.de/CodeSystem/KBV_CS_MIO_EMP_Section_Codes",
              "version" : "1.0.0",
              "display" : "Ãœbergreifende Hinweise-Einträge"
            }
          ]
        },
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.code.coding",
        "path" : "Composition.section.code.coding",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.code.coding.system",
        "path" : "Composition.section.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.code.coding.version",
        "path" : "Composition.section.code.coding.version",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.code.coding.code",
        "path" : "Composition.section.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.code.coding.display",
        "path" : "Composition.section.code.coding.display",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Composition.section:hinweisEintraege.entry",
        "path" : "Composition.section.entry",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "https://fhir.kbv.de/StructureDefinition/KBV_PR_MIO_EMP_Observation_Medication_Management_Note|1.0.0"
            ]
          }
        ]
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.